Tools


Site Explorer

Site Explorer

SOMATOM go.Now

Run a successful CT business

SOMATOM go.Now helps you turn complex exams into clinical routine. Thanks to premium technologies, it delivers results that were previously only available on high-end scanners.

  • Fast and efficient routine scanning
  • High-quality CT angiography
  • Speed and accuracy in routine neuro examinations
  • Broaden your portfolio in preventive care
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Reducing metal artifacts with iMAR; spiral 0.7 mm acquisition, 3 mm axial recon, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Single phase contrast media enhanced scanning of the abdomen; spiral 0.7 mm acquisition, 3 mm coronal recon, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Imaging of the lumbar spine with CARE i-Tilt; spiral 0.7 mm acquisition, spine inline 3 mm MPR ranges, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
CT angiography with low kV setting; spiral 0.7 mm acquisition, VRT + bone removal in CT View&GO, tube voltage 80 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Routine brain imaging with i-Tilt and without contrast media application; spiral 0.7 mm acquisition, inline brain 5 mm MPR recon, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Routine brain imaging with i-Tilt and without contrast media application; spiral 0.7 mm acquisition, inline brain 5 mm MPR recon, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Routine brain imaging with i-Tilt and without contrast media application; spiral 0.7 mm acquisition, inline brain 5 mm MPR recon, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Low-dose lung imaging for nodule visualization; spiral 0.7 mm acquisition, thick slice MIP, tube voltage 110 kV + Tin Filter; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Low-dose lung imaging for tumor detection; spiral 0.7 mm acquisition, coronal 1 mm MPR, tube voltage 110 kV + Tin Filter; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Routine lung imaging for oncology assessment; spiral 0.7 mm acquisition, axial 1 mm MPR, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Siemens Healthineers - CT scanner - SOMATOM go.Now - Clinical Image
Routine lung imaging for oncology assessment; spiral 0.7 mm acquisition, thick-slice MIP, tube voltage 130 kV; Courtesy of University Hospital Erlangen, Germany.
Did this information help you?
Thank you for your response
We detected numbers and/or an '@' symbol in your comment. Are you trying to enter a phone number or email address so that we may contact you, please contact us via our email form instead.

Note: to get a direct personal response, please contact us via our email form.

Thank you